Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
J Clin Med ; 13(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38592176

RESUMO

Background: The aim was to assess three-dimensionally mandibular and maxillary changes in growing Class II patients treated with removable functional appliances followed by fixed appliances. Methods: Twenty-four Class II patients (age range: 9 to 14, mean: 12.1 ± 1.1 years) treated with removable functional appliances followed by fixed appliances (functional appliance group-FAG) were retrospectively selected and compared to an age-matched control group (CG) treated with fixed appliances only. To be included in the study, pre- and post-treatment CBCT scans had to be available. The CBCTs were used to analyze, in 3D, the changes following treatment and growth. Results: Before treatment, overjet (FAG: 9 mm ± 2.8 (mean ± standard deviation); CG: 4 mm ± 1.7), ANB (FAG: 5.7° ± 2.0; CG: 3.2° ± 1.4), and effective mandibular length (FAG: 113.0 mm ± 4.1; CG: 116.6 mm ± 5.9) were statistically significantly different between the two groups. After treatment, overjet (FAG: -6.8 mm ± 2.8; CG: -1.8 mm ± 1.8) and effective mandibular length (FAG: 6.3 mm ± 2.6; CG: 3.9 mm ± 2.6) statistically significantly changed. There was a significant difference in the treatment effect between the FAG and the CG in overjet, ANB, and effective mandibular length. Conclusions: The results indicate that functional appliances are effective in correcting Class II malocclusions. The growth modification in the FAG resulted in an increase in mandibular length. Yet, the final length of the mandible in the FAG was smaller when compared to the CG.

2.
Eur J Orthod ; 46(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38394353

RESUMO

BACKGROUND: CAD/CAM (computer-aided design/computer-aided manufacturing) fixed retainers (FRs) as an alternative to multistranded FRs to maintain orthodontic treatment outcome. OBJECTIVES: The primary aim was to compare CAD/CAM versus conventional multistranded FRs in terms of stability until 2 years. Secondary outcomes were failure rates, patient satisfaction, and cost-minimization. TRIAL DESIGN: 2-arm parallel, two-centre randomized controlled trial. METHODS: Patients were randomized to CAD/CAM or conventional FRs in both arches, in a 1:1 ratio and blocks of four. Allocation concealment was secured by using sequentially numbered envelopes. Patients were blinded. FRs were bonded at the end of treatment, and patients were recalled after 12 and 24 months. First-time retainer failures were recorded and digital impressions were taken. Arch widths and lengths, as well as Little's Irregularity Index (LII), were measured. Additionally, patients answered satisfaction questionnaires. Linear mixed models were applied for measurements and patient satisfaction. Survival analyses were estimated with Kaplan-Meier curves, along with Cox-regression modelling. Cost-minimization analysis was undertaken. RESULTS: One hundred and eighty-one patients were randomized (98 in Centre 1, and 83 in Centre 2): 90 in CAD/CAM and 91 in conventional group. One hundred and fifty three patients attended T24 follow-up. There were no significant differences in LII and arch dimensions between groups for failure-free patients. Within 24 months, 34% maxillary CAD/CAM FRs and 38% maxillary conventional FRs failed, along with 42% mandibular CAD/CAM FRs and 40% mandibular conventional FRs, with no significant difference in survival between groups (hazard ratios conventional to CAD/CAM: maxillary arch: 1.20 [P = 0.46], mandibular arch: 0.98 [P = 0.94]). There were no significant differences in patient satisfaction between groups. No harms were observed. Cost-minimization analysis showed that CAD/CAM FRs were slightly cheaper than conventional FRs. CONCLUSIONS: There were no clinically significant differences in LII, arch widths, and lengths between CAD/CAM and conventional FRs after 24 months. There were no differences in failures and patient satisfaction between groups. CAD/CAM FRs were slightly cheaper than conventional FRs. TRIAL REGISTRATION: ClinicalTrials.gov NCT04389879.


Assuntos
Contenções Ortodônticas , Satisfação do Paciente , Humanos , Seguimentos , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Fixos
3.
J Clin Med ; 12(24)2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38137761

RESUMO

(1) Aims: The main objective of this retrospective study was to assess the long-term stability of difficult orthodontic treatments treated to an excellent result and to correlate stability to possible prognostic factors. Secondary objectives were to observe the changes in retention protocol over time and to assess Oral Health-related Quality of Life (OHRQoL) after a long-term post-treatment follow-up. (2) Methods: Cases presented for final examination by orthodontic postgraduate students were retrospectively screened for eligibility. Eligible patients were recalled for a post-treatment recall appointment (T2), consisting of a clinical examination and intraoral scan, and were asked to complete the Oral Health Impact Profile-14 (OHIP-14-DK). Gender, age at treatment commencement (T0), treatment modality and duration, and retention protocol were extracted from the records. At T2, the duration of the retention period was recorded, and retainers in place were clinically compared to the original retention protocol. The following variables were assessed on the sets of models at T0, T1 (end of treatment), and T2: arch length and width, overjet and overbite, Dental Aesthetic Index (DAI), Peer Assessment Rating score (PAR), and Little's Irregularity Index (LII). Multiple regression models were conducted. (3) Results: Eighty-five subjects attended T2. The mean post-treatment follow-up was 9.4 years +/- 2.4. In the upper arch, at T1, 74 patients had a combination of fixed and removable retainers, while at T2, 55 had a fixed retainer only. In the lower arch, at T1, 67 patients had a fixed retainer only, with this number increasing to 76 at T2. From T0 to T1, the PAR score improved by 96.1%, with the improvement remaining at 77.5% at T2. The stability of lower inter-canine and upper inter-premolar widths was significantly correlated with the extent of changes during treatment. The presence of a lower fixed retainer at T2 and a low LII at T1 were prognostic factors for stability. The mean weighted total OHIP-14 score at T2 was very low (1.6 ± 2.4 points). (4) Conclusions: In a sample with an initial high-severity malocclusion and treated to an excellent outcome, long-term stability was very good. Good stability can be retained when a lower fixed retainer is present at T2 and when a low LII is achieved at T1.

4.
Eur J Orthod ; 45(1): 58-67, 2023 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-35964235

RESUMO

OBJECTIVES: The primary aim of this two-arm parallel two-centre randomized controlled trial was to compare computer-aided design and computer-aided manufacturing (CAD/CAM) versus conventional multistranded fixed retainers (FRs) in terms of stability over 6 months. Secondary outcomes were failure rates and patient satisfaction. METHODS: Patients were randomized to CAD/CAM or conventional FRs in both arches, in 1:1 ratio and blocks of four. Allocation concealment was secured by using sequentially numbered envelopes. Patients were blinded. Retainers were bonded at the end of orthodontic treatment (T0), and patients were recalled after 1 (T1), 3 (T3), and 6 (T6) months. First-time retainer failures were recorded and digital impressions were taken. Arch widths and lengths, as well as Little's Irregularity Index (LII), were measured. Additionally, patients answered satisfaction questionnaires. Linear mixed models were applied for measurements and patient satisfaction. Survival analyses were estimated with Kaplan-Meier curves, along with Cox-regression modelling. RESULTS: One hundred and eighty-one patients were randomized (98 in Centre 1, and 83 in Centre 2): Ninety in the CAD/CAM group and 91 in the conventional group. Three subjects dropped out at baseline, as they did not attend any of the follow-up appointments.168 patients attended the T6 visit. There were no significant differences in arch dimensions between T0 and T6, whilst the LII was different only in the CAD/CAM group (mean difference: 0.2 mm; 95% confidence interval: 0.1 to 0.4; P < 0.001). Within 6 months, 39 upper retainers (19 out of 88 CAD/CAM and 20 out of 90 conventional retainers) and 52 lower retainers failed (26 out of 88 CAD/CAM and 26 out of 90 conventional retainers), with no significant difference between the survival of both types of retainers (hazard ratios conventional to CAD/CAM: upper arch: 0.99 [P =0.99], lower arch: 0.93 [P = 0.80]). There were no significant changes in patient satisfaction between the groups. No harms were observed. CONCLUSIONS: There were no clinically significant differences in LII, arch widths and lengths between CAD/CAM and conventional retainers after 6 months. There was no difference in failures and in patient satisfaction between both types of FRs. REGISTRATION: ClinicalTrials.gov NCT04389879.


Assuntos
Contenções Ortodônticas , Satisfação do Paciente , Humanos , Seguimentos , Contenções Ortodônticas/efeitos adversos , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Fixos
6.
Clin Exp Dent Res ; 8(6): 1456-1466, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36017763

RESUMO

OBJECTIVE: Operating time is one of the main advantages attributed from the literature to the use of self-ligating brackets (SLB). The aim of this study is to investigate the time needed for a complete archwire change procedure with conventional brackets (CB) and SLBs in a standardized in vitro research setting, comparing operators with different expertise. MATERIALS AND METHODS: Thirty-three participants were divided into three equal groups: undergraduate students, postgraduate students, and orthodontists. Three sets of typodonts bonded with three types of brackets, including passive SLBs, active SLBs, and CBs using both steel and elastic ligatures were investigated. Operators had to insert, ligate, deligate, and remove wires in sets of typodonts representing an actual dentition before and after orthodontic treatment, mounted in phantoms. Archwire change procedure times were compared between the different bracket/ligation systems, between the before- and after-treatment typodonts, and between operators. RESULTS: There were significant differences between SLBs and CBs, the greatest difference being 11 min 16 s between passive SLBs and CBs ligated with metallic ligatures at T0, for the total archwire change procedure by the operators overall. For all the operators, there was a statistically significant difference in total archwire change procedure time between the systems. The undergraduate students were the slowest when using CBs, but they showed no significant difference compared to the other users when using SLBs. CONCLUSION: SLBs can offer a significant operating time reduction compared to CBs, and time saving is not dependent on the operator's experience and training.


Assuntos
Braquetes Ortodônticos , Fios Ortodônticos , Humanos , Desenho de Aparelho Ortodôntico
7.
Am J Orthod Dentofacial Orthop ; 162(2): 152-161.e1, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35551840

RESUMO

INTRODUCTION: This 2-arm parallel trial aimed to assess the number of failures of mandibular fixed retainers bonded with direct and indirect bonding methods at a 5-year follow-up and investigate the stability of intercanine and interpremolar distances. METHODS: Consecutive patients from the clinic of the University of Geneva (Switzerland) were randomly allocated to either direct or indirect bonding of a mandibular fixed retainer at the end of orthodontic treatment. Inclusion criteria included the presence of all mandibular incisors and canines; and the absence of active caries, restorations, fractures, or periodontal disease of these teeth. The patients were randomized in blocks of 4 using an online randomization service, with allocation concealment secured by contacting the sequence generator for assignment. Two and 5 years (T5) after bonding the retainers, the patients were recalled, and impressions were taken. The primary outcome was the 5-year survival of the mandibular fixed retainer bonded with both bonding methods. The secondary outcomes were the intercanine and interpremolar distances and the assessment of unexpected posttreatment changes (ie, changes in torque and/or rotations of the mandibular incisors and canines). Blinding was applicable for outcome assessment only. Kaplan-Meier curves were generated, and a Cox proportional hazard regression model was fitted for bonding type, age, and treatment. Linear mixed models were fitted to intercanine and interpremolar distances: bonding type, time, age, and treatment were modeled as outcomes. RESULTS: Sixty-four patients were randomized in a 1:1 ratio. At T5, 6 patients without previous failure were lost to follow-up from each group. At T5, the fixed retainer was debonded in 14 patients (54%) for each group. The hazard ratio of indirect bonding to direct bonding was 1.09 (95% confidence interval, 0.26-4.60; P = 0.91); there was no statistically significant difference in survival between the groups. Regarding intercanine and interpremolar distances, none of the tested prognostic factors reached statistical significance. Unexpected posttreatment changes were observed in 6 failure-free patients, all bonded with the direct bonding method. Only 1 patient required debonding of the fixed retainer. No other serious harms were observed. CONCLUSIONS: The 5-year survival rate for both direct and indirect bonding methods was 46%, without a statistically significant difference between bonding methods. Bonded retainers were effective in maintaining intercanine and interpremolar distances. Unexpected posttreatment changes were only observed with retainers bonded with the direct bonding method. REGISTRATION: The trial was not registered. PROTOCOL: The protocol was not published before trial commencement. FUNDING: No funding or conflict of interest to be declared.


Assuntos
Colagem Dentária , Contenções Ortodônticas , Colagem Dentária/métodos , Seguimentos , Humanos , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Fixos , Contenções Ortodônticas/efeitos adversos
8.
Front Bioeng Biotechnol ; 10: 840622, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35372304

RESUMO

Aim: To evaluate in vitro the differences of various Invisalign® attachments in their effectiveness during derotation of an upper second premolar in terms of forces and moments created and compare them to the 3Shape® box attachment as well as to no attachment at all. Materials and Methods: A Force System Identification (FSI) machine, comprising two load sensors, was used in this study. Sensor 1 was connected to the test tooth (i.e. upper second premolar) carrying a different attachment design, and the fixed sensor (Sensor 2) was connected to the base model. Once the corresponding aligner was passively seated on the teeth, 12 different setups (i.e. 11 different attachments and one setup with no attachment at all) were tested by rotating the test tooth 4.5° mesially and 4.5° distally, in increments of 0.45°. Results: The vertical rectangular attachments were able to generate the highest derotational moment on both mesial and distal rotations but also received the most side effects (intrusive force, torque, and tipping). The no-attachment setup performed least favorably in terms of derotational ability but exhibited the least side effects. In the y-axis, all attachments received a buccal root torque with a lingual force during disto-rotation and a lingual root torque with a buccal force during mesio-rotation. Conclusion: Attachments are necessary for derotating an upper second premolar. An aligner incremental change of more than 1° derotation can generate high moments. The vertical rectangular attachments perform best in derotations; however, they exhibit the most side effects. Finally, despite presenting the least side effects, derotation of a premolar with no attachment is not as efficient.

9.
Acta Odontol Scand ; 80(6): 411-418, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35044870

RESUMO

OBJECTIVE/BACKGROUND: Sleep-disordered breathing (SDB) is common but often underestimated in children. The gold standard for assessing SDB is polysomnography, but it is expensive and time-consuming. The Paediatric Sleep Questionnaire (PSQ/SRDB) is a validated screening tool for SDB, which represents an efficient and alternative tool for screening SDB among children. However, a translated and validated Danish version of the PSQ/SRDB is not available yet. Our aim was to cross-culturally translate the PSQ/SRDB into Danish language for use in clinical and research settings. PATIENTS/METHODS: The translation was carried out through forward-backward translation techniques performed by a panel of experts, and the cross-cultural adaptation was achieved by pretesting of the pre-final version. Internal consistency of the Danish PSQ/SRDB version was measured by Cronbach's alpha coefficients, while Cohen's kappa was used to evaluate test-retest reliability. Construct validity was assessed by factor analysis of the principal components. RESULTS: The Danish PSQ/SRDB was administered to the caregivers of 348 children. An overall Cronbach's alpha of 0.72 was found, confirming the survey's consistency, with the results for the domains ranging 0.52-0.70. The Danish PSQ/SRDB showed moderate to perfect reliability for all items, except for one question (C14). Factor analysis performed on the Danish PSQ/SRDB showed that the predetermined four factors were similar with the original version of the PSQ/SRDB. CONCLUSIONS: The Danish version of the PSQ/SRDB has been successfully translated and cross-culturally adapted, suggesting that it can be used as an appropriate paediatric screening tool for SDB in Denmark.


Assuntos
Comparação Transcultural , Síndromes da Apneia do Sono , Criança , Dinamarca , Humanos , Idioma , Psicometria , Reprodutibilidade dos Testes , Sono , Síndromes da Apneia do Sono/diagnóstico , Inquéritos e Questionários
10.
Orthod Craniofac Res ; 25(3): 368-376, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34738713

RESUMO

OBJECTIVE: The present study aimed to evaluate stability 2 years after orthodontic treatment and to investigate the influence of various pre-treatment and post-treatment prognostic factors on stability. SETTING AND SAMPLE POPULATION: Consecutive patients treated with full fixed appliance and retained with fixed retainers were retrospectively assessed for eligibility. MATERIALS AND METHODS: Digital models were analysed at treatment start (T0), end of treatment (T1) and 2 years post-treatment (T2). The Peer Assessment Rating (PAR) index, Little's Irregularity Index (LII), arch width and length, overjet, overbite and presence of unexpected post-treatment changes were assessed. Multiple regression analyses were conducted to model the relationship of all outcomes with several prognostics simultaneously. RESULTS: The sample consisted of 287 subjects (mean treatment time: 25.1 months, standard deviation [SD] 7.5; mean post-treatment follow-up: 27.5 months, SD 6.1) with a mean weighted PAR score of 29.5 (SD 8.6) at T0, 1.8 (SD 2.9) at T1 and 3.2 (SD 3.6) at T2. At T1, 95% of the subjects had a perfect LII versus 86% at T2. An increased LII at T1 correlated with increased LII and PAR changes from T1 to T2. PAR at T1 as well as overjet at T0 was a significant prognostic factor for PAR at T2. At T2, five cases (1.7%) showed unexpected post-treatment changes related to fixed retainers. CONCLUSION: Short-term post-treatment stability with fixed retainers was very good. Prognostic factors for stability included LII and PAR at T1, suggesting that high-quality treatment outcome in the presence of fixed retainers may ensure post-treatment stability.


Assuntos
Contenções Ortodônticas , Sobremordida , Humanos , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Fixos , Ortodontia Corretiva , Sobremordida/terapia , Estudos Retrospectivos , Resultado do Tratamento
11.
Acta Odontol Scand ; 80(1): 65-73, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34171203

RESUMO

OBJECTIVES: To evaluate and compare malocclusion traits and oral health-related quality of life (OHRQoL) between untreated young adults assessed to have no orthodontic treatment need during childhood, and young adults treated orthodontically during childhood. In addition, to investigate the relationship between malocclusion and OHRQoL. MATERIALS AND METHODS: One hundred undergraduate students were screened for eligibility. Subjects had intraoral scans and completed OHIP-14 questionnaires. Angle molar relationship, overjet, overbite, arch length and width, Little's Irregularity Index (LII), Peer Assessment Rating (PAR) index and Dental Aesthetic Index (DAI) scores were assessed. Unpaired t-tests were used to compare outcomes between treated and untreated subjects. Multiple regression analyses were conducted to model the relationship between OHIP-14 and several prognostics simultaneously. RESULTS: Ninety-six subjects were included (mean age ± SD = 23.7 ± 1.8 years): 41 treated and 55 untreated. The untreated subjects had significantly higher LII (p = .02), PAR (p = .01), DAI (p < .01) and overbite (p = .03). The treated subjects had significantly larger inter-canine and inter-premolar distances. No relationship was found between OHIP-14 and LII, PAR, DAI, age, gender and presence/absence of previous orthodontic treatment. However, the DAI score was significantly correlated with the OHIP-14 functional limitation domain. CONCLUSIONS: Untreated subjects had significantly higher LII, PAR and DAI scores than the treated subjects. DAI score was significantly correlated with the OHIP-14 functional limitation domain.


Assuntos
Má Oclusão , Qualidade de Vida , Adolescente , Estudos Transversais , Dinamarca , Humanos , Má Oclusão/terapia , Saúde Bucal
12.
Orthod Craniofac Res ; 25(1): 73-81, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33998771

RESUMO

OBJECTIVE: To assess the efficacy of lingual orthodontics by comparing setups and post-treatment casts. SETTING AND SAMPLE POPULATION: Thirty-two consecutive patients treated with a customized lingual orthodontic appliance were included in this retrospective study. MATERIALS AND METHODS: Initial casts, post-treatment casts and setups were scanned, and the digital models produced were analysed in terms of overjet; overbite; molar and canine relationships; intercanine, interpremolar and intermolar distances; upper and lower arch lengths; midline deviation; bucco-lingual angulation of all teeth and mesio-distal angulation of anterior teeth. Comparisons between setups and post-treatment casts were performed via paired t tests. Relationships between the planned and actual correction were studied using regression analysis. RESULTS: Statistically significant differences in bucco-lingual torque between setups and post-treatment casts were found for all upper teeth, except for central incisors. In the lower jaw, statistically significant differences in bucco-lingual torque were found between setups and post-treatment casts for the lower incisors and molars. No statistically significant differences in mesio-distal angulation of anterior teeth were found between setups and post-treatment casts. Upper and lower arch widths did not vary significantly between setups and final casts, except upper inter-second premolar and intermolar distances. CONCLUSION: Customized lingual appliances offer efficient control of mesio-distal angulation of all anterior teeth. Significant differences in torque between setups and post-treatment casts were observed for upper lateral incisors, canines, premolars and molars, as well as lower incisors and molars. However, the torque difference was clinically significant (over three degrees) for upper second premolars and molars only.


Assuntos
Má Oclusão Classe II de Angle , Ortodontia , Humanos , Incisivo , Má Oclusão Classe II de Angle/terapia , Estudos Retrospectivos , Resultado do Tratamento
13.
Orthod Craniofac Res ; 24 Suppl 2: 124-133, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34352162

RESUMO

OBJECTIVES: To evaluate the three-dimensional changes following rapid maxillary expansion (RME) of the nasal cavity (NC) and pharyngeal airway (PA) in growing patients, using innovative and validated evaluation methods and to investigate whether a correlation between skeletal expansion and increase in airway volume exists. SETTINGS AND SAMPLE POPULATION: Records of patients who had cone beam computed tomography taken before and after orthodontic treatment with or without RME were retrospectively collected and divided into two groups: (a) RME, 39 patients (mean age 10.40 ± 1.74 years); and (b) control, 29 patients, matched for age (mean age 11.07 ± 1.45 years) and follow-up period. MATERIAL AND METHODS: Total and partial volumes of the NC and the PA were calculated. The PA centerline was determined to assess the minimal cross-sectional area and hydraulic diameter. Paired and unpaired t test were applied to compare the difference between time points and between groups. One-way ANOVA and post hoc Tukey's tests were used to compare subgroups with respect to changes in palatal width and lacrimal ducts distance. RESULTS: All of the NC, PA and skeletal parameters were significantly enlarged after RME. The NC volume and inter-molar distance in the RME were significantly larger compared to the control group. The initially lower mean values of minimal cross-sectional area and hydraulic diameter in the RME group when compared to the control group normalized after RME treatment. CONCLUSIONS: Based on validated analyses, the NC volume increase was evident after RME in the long term after controlling for growth.


Assuntos
Cavidade Nasal , Técnica de Expansão Palatina , Criança , Tomografia Computadorizada de Feixe Cônico , Humanos , Maxila , Cavidade Nasal/diagnóstico por imagem , Faringe/diagnóstico por imagem , Estudos Retrospectivos
14.
Orthod Craniofac Res ; 24 Suppl 2: 181-192, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34080292

RESUMO

OBJECTIVES: To assess the soft tissue changes in orthodontic extraction and non-extraction patients on 3D stereophotogrammetric images. SETTING AND SAMPLE: 23 extraction (22.2 ± 9.2 years) and 23 non-extraction (20.3 ± 11.1 years) consecutive patients were enrolled at the Sections of Orthodontics at Aarhus University and at University of Naples Federico II. METHODS: All patients had a first 3D image taken after bonding of brackets on the upper incisors (T0), and a second 3D image (T1) after space closure in the extraction group or at insertion of the first SS or TMA rectangular wire in the non-extraction group. The 3D images were captured with 3dMDFace System and analysed with 3dMDVultus Software. After placing 19 landmarks, 15 measurements were obtained. Intragroup changes were analysed with paired t-test and intergroup changes with unpaired t-test (P < .05). RESULTS: Superimpositions of the 3D images at T0 and T1 visualized with colour-coded maps showed that soft tissue changes primarily happened in the perioral area in both groups. The Nasolabial angle increased significantly in the extraction group (3°± 4.1, P = .002), while it decreased in the non-extraction group (-1.5°± 5.5°, P = .002). There was a significant difference between the two groups (4.4°, P = .004). CONCLUSIONS: 3D comparison of the soft tissues in the extraction and non-extraction groups showed statistically significant, but clinically limited differences in the perioral area. The Nasolabial angle was significantly larger at T1 in the extraction group compared with the non-extraction group.


Assuntos
Imageamento Tridimensional , Fotogrametria , Cefalometria , Humanos , Incisivo , Estudos Prospectivos
15.
J Clin Med ; 10(8)2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-33924334

RESUMO

The aim of this study was to assess the validity and reproducibility of digital scoring of the Peer Assessment Rating (PAR) index and its components using a software, compared with conventional manual scoring on printed model equivalents. The PAR index was scored on 15 cases at pre- and post-treatment stages by two operators using two methods: first, digitally, on direct digital models using Ortho Analyzer software; and second, manually, on printed model equivalents using a digital caliper. All measurements were repeated at a one-week interval. Paired sample t-tests were used to compare PAR scores and its components between both methods and raters. Intra-class correlation coefficients (ICC) were used to compute intra- and inter-rater reproducibility. The error of the method was calculated. The agreement between both methods was analyzed using Bland-Altman plots. There were no significant differences in the mean PAR scores between both methods and both raters. ICC for intra- and inter-rater reproducibility was excellent (≥0.95). All error-of-the-method values were smaller than the associated minimum standard deviation. Bland-Altman plots confirmed the validity of the measurements. PAR scoring on digital models showed excellent validity and reproducibility compared with manual scoring on printed model equivalents by means of a digital caliper.

16.
Angle Orthod ; 91(3): 320-328, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33523094

RESUMO

OBJECTIVES: To assess the intraexaminer and interexaminer reliabilities of novel semiautomatic methods to segment the nasal cavity (NC) and pharyngeal airway (PA) and to determine the minimal cross-sectional area (CS) and hydraulic diameter (HD) of the PA. MATERIALS AND METHODS: To test reproducibility, two examiners analyzed the NC and PA independently in 10 retrospectively selected cone beam computed tomography (CBCT) images using semiautomatic segmentation. The PA centerline was determined to assess the minimal CS and HD. The intraclass correlation coefficient (ICC) was used to calculate intraexaminer and interexaminer reliabilities. Measurement errors were assessed by Dahlberg's formula and paired t-tests. The level of agreement was assessed using the Bland-Altman method. RESULTS: Intraexaminer and interexaminer reliabilities were excellent (minimal ICC, 0.960). The error of the method was good except for interexaminer values for the oropharynx (P = .016). The minimal CS and HD measurements were reliable (minimal ICC, 0.993; narrow limits of agreement). CONCLUSIONS: The novel methods for analysis of the NC and PA are reliable. The minimal CS and HD demonstrated excellent reliabilities, which are critical to detect the most constricted part of the PA. Separation of the oropharynx from the voids close to the retroglossal area is not trivial and should be considered with caution.


Assuntos
Imageamento Tridimensional , Cavidade Nasal , Cefalometria , Tomografia Computadorizada de Feixe Cônico , Cavidade Nasal/diagnóstico por imagem , Faringe/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
Curr Osteoporos Rep ; 19(2): 175-181, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33538966

RESUMO

PURPOSE OF REVIEW: To produce an updated overview of the use of finite element (FE) analysis for analyzing orthodontic tooth movement (OTM). Different levels of simulation complexity, including material properties and level of morphological representation of the alveolar complex, will be presented and evaluated, and the limitations will be discussed. RECENT FINDINGS: Complex formulations of the PDL have been proposed, which might be able to correctly predict the behavior of the PDL both when chewing forces and orthodontic forces are simulated in FE models. The recent findings do not corroborate the simplified view of the classical OTM theories. The use of complex and biologically coherent FE models can help understanding the mechanisms leading to OTM as well as predicting the risk of root resorption related to specific force systems and magnitudes.


Assuntos
Análise de Elementos Finitos , Técnicas de Movimentação Dentária , Fenômenos Biomecânicos , Simulação por Computador , Humanos
18.
Am J Orthod Dentofacial Orthop ; 159(1): 125-132, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33223373

RESUMO

The purpose of this clinical report is to illustrate an innovative treatment plan for a patient with Class III malocclusion. The plan combined the versatility of computer-aided design and manufacturing technology with miniscrews. Maxillary and mandibular fully customized metal framework anchored to 4 miniscrews was digitally designed and constructed for a growing patient with midface hypoplasia and a skeletal Class III malocclusion. The patient wore Class III elastics between hooks on the maxillary and mandibular frameworks full time for 10 months. Overcorrection was obtained with limited dental side effects, and a significant improvement of the profile was achieved. With the advantages of computer-aided design and manufacturing technology and less invasive insertion procedure compared with miniplate surgery, this patient-specific treatment approach was simple and effective.


Assuntos
Má Oclusão Classe III de Angle , Procedimentos de Ancoragem Ortodôntica , Cefalometria , Desenho Assistido por Computador , Humanos , Má Oclusão Classe III de Angle/diagnóstico por imagem , Má Oclusão Classe III de Angle/terapia , Mandíbula , Maxila/cirurgia , Técnica de Expansão Palatina
19.
Eur J Orthod ; 43(2): 144-151, 2021 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-32780096

RESUMO

INTRODUCTION: The primary aim of this randomized controlled trial was to compare the time for bracket bonding using either direct or computer-aided indirect bonding; a secondary aim was to assess immediate bracket debondings and cost minimization. METHODS: Consecutive patients were randomly allocated to two groups (blocks of four, online-generated sequence) using a split-mouth design with a direct and a computer-aided indirect bonding method: group 1 (upper right and lower left quadrants: indirect bonding; upper left and lower right quadrants: direct bonding) or group 2 (opposite situation). The primary outcome was difference in time spent for bonding brackets. The secondary outcome was immediate bracket debondings (at the bonding appointment). Time for indirect bonding was recorded in two steps: digital bracket placement and clinical bonding procedure. Outcome assessment was blinded. Friedman's ANOVA test was used to assess differences in bonding time. Chi-square test was used to compare immediate debondings. A cost-minimization analysis was undertaken. RESULTS: Thirty-seven patients were randomized to group 1 or 2. Ten patients were excluded: 15 patients were analyzed in group 1 and 12 in group 2. Clinical chair time for bonding half a mouth was significantly shorter for computer-aided indirect bonding (12 minutes 52 seconds) than for direct bonding (16 minutes 47 seconds) (P < 0.001). When adding the time for digital bracket placement, the total bonding time (28 minutes 14 seconds) was longer for indirect bonding than for direct bonding (P < 0.001). There was no single immediate debonding with the direct bonding method, while 14 brackets were lost with the indirect bonding method (5.1 per cent) (P = 0.0001). Cost-minimization analysis showed that computer-aided indirect bonding was more expensive than direct bonding. CONCLUSIONS: The clinical chair time was significantly shorter for computer-aided indirect bonding than for direct bonding. However, the total bonding time for computer-aided indirect, including digital bracket placement, was longer than for direct bonding. There were significantly more immediate debondings with computer-aided indirect bonding than with direct bonding. Under these conditions, computer-aided indirect bonding was more expensive than direct bonding. REGISTRATION: This trial was retrospectively registered on ClinicalTrials.gov (University of Aarhus Protocol Record 10101). PROTOCOL: The protocol was not published before trial commencement.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Computadores , Humanos
20.
Eur J Orthod ; 43(1): 51-68, 2021 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-32815989

RESUMO

OBJECTIVE: The aim of this systematic review was to determine which evidence level supports maxillary advancement after bone-anchored maxillary protraction (BAMP) in growing patients compared to controls. SEARCH METHODS: PubMed, Cochrane, Embase, Scopus, and Web-of-Science databases were searched with no restrictions on publication status or year. SELECTION CRITERIA: Prospective and retrospective human studies about BAMP, in at least three patients, were included. Authors were contacted when necessary, and reference lists of the included studies were screened. DATA COLLECTION AND ANALYSIS: Two authors undertook independent data extraction with conflict resolution by a third author. Risks of bias were assessed. A meta-analysis for estimates of changes for ANB angle, Wits appraisal, and incisor to mandibular plane angle (IMPA) angle of BAMP treatment compared to control groups was performed. RESULTS: A total of 449 articles were initially retrieved; 28 full-text articles met the inclusion criteria. Sample sizes ranged from 3 to 52 patients. There was heterogeneity in cephalometric outcomes reported, which prevented the comparison of certain outcomes. ANB angle improved more with BAMP in the maxilla combined with facemask (bone-anchored facemask, BAFM) compared to traditional facemask therapy: this was statistically but not clinically significant (0.2 degrees). No data are available for BAMP with skeletal anchorage in both jaws in combination with Class III elastics (bone-anchored Class III elastics, BAC3E). Likewise, no statistically significant differences in Wits appraisal were found (less than 1 mm). Lower incisor retroclination and facial height seemed to be better controlled with BAC3E compared to BAFM. CONCLUSIONS: The level of evidence available to support the maxillary advancement effect after BAMP was low. Publications reporting results based on identical samples tended to suggest overly positive results of BAMP. The differences in sagittal correction between BAMP and traditional facemask therapy were small and of questionable clinical significance. Long-term follow-up results are not available and, therefore, much needed. LIMITATIONS: Most articles had a low level of evidence and some included a historical control group. REGISTRATION: PROSPERO database number CRD42015023366.


Assuntos
Má Oclusão Classe III de Angle , Maxila , Cefalometria , Aparelhos de Tração Extrabucal , Humanos , Má Oclusão Classe III de Angle/diagnóstico por imagem , Má Oclusão Classe III de Angle/terapia , Técnica de Expansão Palatina , Estudos Prospectivos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...